Important: The information presented here is for the use of a qualified, experienced technician. Without the background knowledge which comes with training, you risk doing more damage then good to the copier & also risk your own safety. If you are not willing to take 100% responsibility for your actions, do not use the information posted here. Thank you. Read our conditions of Use for more information.
DC250 style - Fault Codes 061 - Laser Scan Failures
DC250 style - Fault Codes 061 - Laser Scan Failures
Technical Specifications |
---|
DC250 style Fault Codes 061 (Laser Scan Failures)
061 Fault Codes – Laser Scan Failures
061-310 – Clapper 1 Failure
The write data and read data did not match during the Read/Write test to the register memory
061-311 – Clapper 2 Failure
The write data and read data did not match during the Read/Write test to the register memory
061-313 – SOS Long Failure Magenta
The interval between SOS signals was longer than the specified value.
061-315 – SOS Long Failure Black
The interval between SOS signals was longer than the specified value.
061-317 – SOS Short Failure Magenta
The interval between SOS signals was shorter than the specified value.
061-319 – SOS Short Failure Black
The interval between SOS signals was shorter than the specified value.
061-320 – Polygon Motor Failure
The revolutions of the polygon motor did not reach the proper number of revolutions within 4 seconds after the polygon motor came on
061-321 – ROS Motor Failure
061-323 – No SOS Failure Magenta
The SOS signal was not detected
061-324 – No SOS Failure Cyan
The SOS signal was not detected.
061-325 – No SOS Failure Black
The SOS signal was not detected.
061-326 – ROS Connect Failure Yellow
The connection between the ROS LD and the MCU PWB failed.
061-327 – ROS Connect Failure Magenta
The connection between the ROS LD and the MCU PWB failed.
061-328 – ROS Connect Failure Cyan
The connection between the ROS LD and the MCU PWB failed.
061-329 – ROS Connect Failure Black
The connection between the ROS LD and the MCU PWB failed.
061-334 – ROS Yellow/Magenta VDD Failure
061-335 – ROS Black/Cyan VDD Failure
061-336 – ROS Yellow/Magenta VDD Down Failure
061-337 – ROS Black/Cyan VDD Down Failure
061-338 – SOS Stop Magenta Failure
061-339 – SOS Stop Black Failure
061-340 – ROS LD Failure Black
At least three channels (NVM 749-105) of the 32 channels had detected LD degradation when the LD alarm was generated.
061-341 – ROS LD Failure Yellow
At least three channels (NVM 749-105) of the 32 channels had detected LD degradation when the LD alarm was generated.
061-342 – ROS LD Failure Magenta
At least three channels (NVM 749-105) of the 32 channels had detected LD degradation when the LD alarm was generated.
061-343 – ROS LD Failure Cyan
At least three channels (NVM 749-105) of the 32 channels had detected LD degradation when the LD alarm was generated.
061-600 – ROS Data Failure Yellow
Serial data communication is not possible between the MCU PWB and ROS (hidden failure).
061-601 – ROS Data Failure Magenta
Serial data communication is not possible between the MCU PWB and ROS (hidden failure).
061-602 – ROS Data Failure Cyan
Serial data communication is not possible between the MCU PWB and ROS (hidden failure).
061-603 – ROS Data Failure Black
Serial data communication is not possible between the MCU PWB and ROS (hidden failure).
061-604 – LD Alarm Yellow
A problem occurred in one of the 32 beams (hidden failure).
061-605 – LD Alarm Magenta
A problem occurred in one of the 32 beams (hidden failure).
061-606 – LD Alarm Cyan
A problem occurred in one of the 32 beams (hidden failure).
061-607 – LD Alarm Black
A problem occurred in one of the 32 beams (hidden failure).
|