Important: The information presented here is for the use of a qualified, experienced technician. Without the background knowledge which comes with training, you risk doing more damage then good to the copier & also risk your own safety. If you are not willing to take 100% responsibility for your actions, do not use the information posted here. Thank you. Read our conditions of Use for more information.


DC250 style - Fault Codes 010 - Fuser Faults

DC250 style - Fault Code2 - 010 - Fuser Faults

Technical Specifications

DC250 style

Fault Codes 010 Fuser Faults

  

010-311 – Fuser Heat Roll STS-1 Disconnection Fail
Fuser heat roll STS-1 was disconnected.

 

010-319 – Fuser NC Sensor Differential Amp Fail
 

010-320 – Heat Roll Overheat Fail
Fuser Heat Roll STS-1, STS-2, or STS-3 became too hot.

 

010-321 – Fuser Nip Fail
 

010-322 – Fuser NC Center Sensor Disconnection Fail
(Fuser Temperature Sensor Fail)

 

010-323 – Fuser Rear Disconnection Fail
(Fuser Temperature Sensor Fail)

 

010-324 – Fuser NVM Fail
 

010-326 – Wait Heat Roll Fuser On Time Fail
Main lamp #1, main lamp #2, or the sub lamp is continually flashing abnormally during wait state.

 

010-327 – Standby Heat Roll Fuser On Time Fail
 
Main lamp #1, main lamp #2, or the sub lamp is continually flashing during standby state or low power state.

 

010-330 – Fuser Motor Fail
A rotation abnormality was detected in the fuser motor.

 

010-420 – Fuser Assembly Life Near End
Almost time to replace the fuser assembly.